TN 3270 problem |
|
|
am facing a problem configuring TN3270 Service on HIS 2004
I have configured LUA pool with 5 LUAs
the problem that the first two client successfully connect but any other
client after that get error message on the emulator screen saying
TN3270E Service Message 525
The PU is active for LU X(were X is LU Name)
You may continue to wait or terminate your session
that's the error and the status of the LUs that fail keep on going in
pending |
|
| Back to top |
|
 |
Charles Ezzell (MSFT)
Guest
|
Posted:
Wed Oct 05, 2005 4:51 pm Post subject:
Re: TN 3270 problem |
|
|
If the LUs on the connection are in a pending state, that is not a TN issue,
but a configration issue between HIS and the mainframe. You should check
with your mainframe people that these LUs are actually available on the
host, and see what the status of the LUs are for them.
--
HTH,
Charles Ezzell
Microsoft
This posting is provided "AS IS" with no warranties, and confers no rights.
Use of any included samples are subject to the terms specified at
http://www.microsoft.com/info/cpyright.htm
"Ahmed Ezz El Din" <ahm_ezz@hotmail.com> wrote in message
news:OLG4LKbyFHA.460@TK2MSFTNGP15.phx.gbl...
| Quote: | am facing a problem configuring TN3270 Service on HIS 2004
I have configured LUA pool with 5 LUAs
the problem that the first two client successfully connect but any other
client after that get error message on the emulator screen saying
TN3270E Service Message 525
The PU is active for LU X(were X is LU Name)
You may continue to wait or terminate your session
that's the error and the status of the LUs that fail keep on going in
pending
|
|
|
| Back to top |
|
 |
Neil Pike
Guest
|
Posted:
Wed Oct 05, 2005 8:51 pm Post subject:
Re: TN 3270 problem |
|
|
Ahmed,
Does the PU on the mainframe definitely have (at least) 5 display LU's defined
with the right LU numbers? My guess is that LU's "3" onwards either aren't
defined on the mainframe or are defined incorrectly.
| Quote: | am facing a problem configuring TN3270 Service on HIS 2004
I have configured LUA pool with 5 LUAs
the problem that the first two client successfully connect but any other
client after that get error message on the emulator screen saying
TN3270E Service Message 525
The PU is active for LU X(were X is LU Name)
You may continue to wait or terminate your session
that's the error and the status of the LUs that fail keep on going in
pending
|
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP |
|
| Back to top |
|
 |
Ahmed Ezz El Din
Guest
|
Posted:
Thu Oct 06, 2005 5:56 am Post subject:
Re: TN 3270 problem |
|
|
i though so also Neil just wanted to make sure
what i suspect that the mainframe guy is trying to get the project down and
he is not doing the right configuration
i guess i will have to visit the client again and look at the PU setting
myself
Cheers
Ahmed
"Neil Pike" <neilpike@compuserve.com> wrote in message
news:VA.00006333.0b304fc0@compuserve.com...
| Quote: | Ahmed,
Does the PU on the mainframe definitely have (at least) 5 display LU's
defined
with the right LU numbers? My guess is that LU's "3" onwards either
aren't
defined on the mainframe or are defined incorrectly.
am facing a problem configuring TN3270 Service on HIS 2004
I have configured LUA pool with 5 LUAs
the problem that the first two client successfully connect but any other
client after that get error message on the emulator screen saying
TN3270E Service Message 525
The PU is active for LU X(were X is LU Name)
You may continue to wait or terminate your session
that's the error and the status of the LUs that fail keep on going in
pending
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP
|
|
|
| Back to top |
|
 |
Neil Pike
Guest
|
Posted:
Thu Oct 06, 2005 4:52 pm Post subject:
Re: TN 3270 problem |
|
|
Not good news if they're deliberately trying to make it fail!
You could ask them to send you a display of the PU out of netview, that would
show what was defined/running.
| Quote: | i though so also Neil just wanted to make sure
what i suspect that the mainframe guy is trying to get the project down and
he is not doing the right configuration
i guess i will have to visit the client again and look at the PU setting
myself
|
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP |
|
| Back to top |
|
 |
Ahmed Ezz El Din
Guest
|
Posted:
Thu Oct 20, 2005 12:52 am Post subject:
Re: TN 3270 problem |
|
|
hi Neil
i got the guy to send me the PU definition which i suspect something wrong
with it
the PU definition he sent me is
*
PUE PU ADDR=C6,PUTYPE=2,NETID=NETA,MAXPATH=3,
MAXDATA=2012,DLOGMOD=D4A32XX3,ASDP=YET,
LANSW=YES,IDBLK=05D,IDNUM=00006
LUE LU LOCADDR=0,DLOGMOD=IBMRDB,ISTATUS=ACTIVE
PET11 LU LOCADDR=2, ISTATUS=ACTIVE,LOGAPPL=VM
PET12 LU LOCADDR=3, ISTATUS=ACTIVE,LOGAPPL=VM
PET15 LU LOCADDR=4, ISTATUS=ACTIVE,LOGAPPL=VM
PET16 LU LOCADDR=5, ISTATUS=ACTIVE,LOGAPPL=VM
PET17 LU LOCADDR=6, ISTATUS=ACTIVE,LOGAPPL=VM
PET18 LU LOCADDR=7, ISTATUS=ACTIVE,LOGAPPL=VM
PET19 LU LOCADDR=8, ISTATUS=ACTIVE,LOGAPPL=VM
PET20 LU LOCADDR=9, ISTATUS=ACTIVE,LOGAPPL=VM
*
i also got a server traces from HIS and sent to a friend in microsoft who
confirmed that the host is sending only two active LUs however in the
definition there's 8 LUs any ideas what to check or what might be configured
wrong
thanks alot for your help
/Ahmed
"Neil Pike" <neilpike@compuserve.com> wrote in message
news:VA.00006336.00df71d2@compuserve.com...
| Quote: | Not good news if they're deliberately trying to make it fail!
You could ask them to send you a display of the PU out of netview, that
would
show what was defined/running.
i though so also Neil just wanted to make sure
what i suspect that the mainframe guy is trying to get the project down
and
he is not doing the right configuration
i guess i will have to visit the client again and look at the PU setting
myself
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP
|
|
|
| Back to top |
|
 |
Neil Pike
Guest
|
Posted:
Thu Oct 20, 2005 4:51 pm Post subject:
Re: TN 3270 problem |
|
|
Ahmed,
I think it's the MAXPATH param that's doing you in. It's set to 3 which is
allowing LU 0 (I presume an appc/lu62 definition) and LU's 2 and 3 to go
active. Which totals 3 - the maximum defined.
Get that parameter removed and it will allow all LU's on the PU to go active.
| Quote: | i got the guy to send me the PU definition which i suspect something wrong
with it
the PU definition he sent me is
*
PUE PU ADDR=C6,PUTYPE=2,NETID=NETA,MAXPATH=3,
MAXDATA=2012,DLOGMOD=D4A32XX3,ASDP=YET,
LANSW=YES,IDBLK=05D,IDNUM=00006
LUE LU LOCADDR=0,DLOGMOD=IBMRDB,ISTATUS=ACTIVE
PET11 LU LOCADDR=2, ISTATUS=ACTIVE,LOGAPPL=VM
PET12 LU LOCADDR=3, ISTATUS=ACTIVE,LOGAPPL=VM
PET15 LU LOCADDR=4, ISTATUS=ACTIVE,LOGAPPL=VM
PET16 LU LOCADDR=5, ISTATUS=ACTIVE,LOGAPPL=VM
PET17 LU LOCADDR=6, ISTATUS=ACTIVE,LOGAPPL=VM
PET18 LU LOCADDR=7, ISTATUS=ACTIVE,LOGAPPL=VM
PET19 LU LOCADDR=8, ISTATUS=ACTIVE,LOGAPPL=VM
PET20 LU LOCADDR=9, ISTATUS=ACTIVE,LOGAPPL=VM
*
i also got a server traces from HIS and sent to a friend in microsoft who
confirmed that the host is sending only two active LUs however in the
definition there's 8 LUs any ideas what to check or what might be configured
wrong
thanks alot for your help
/Ahmed
"Neil Pike" <neilpike@compuserve.com> wrote in message
news:VA.00006336.00df71d2@compuserve.com...
Not good news if they're deliberately trying to make it fail!
You could ask them to send you a display of the PU out of netview, that
would
show what was defined/running.
i though so also Neil just wanted to make sure
what i suspect that the mainframe guy is trying to get the project down
and
he is not doing the right configuration
i guess i will have to visit the client again and look at the PU setting
myself
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP
|
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP |
|
| Back to top |
|
 |
Ahmed Ezz El Din
Guest
|
Posted:
Thu Oct 20, 2005 4:51 pm Post subject:
Re: TN 3270 problem |
|
|
i though that could be the problem also i will try it and update you with
the result :)
thanks alot Neil
/Ahmed
"Neil Pike" <neilpike@compuserve.com> wrote in message
news:VA.00006353.007d94d8@compuserve.com...
| Quote: | Ahmed,
I think it's the MAXPATH param that's doing you in. It's set to 3 which
is
allowing LU 0 (I presume an appc/lu62 definition) and LU's 2 and 3 to go
active. Which totals 3 - the maximum defined.
Get that parameter removed and it will allow all LU's on the PU to go
active.
i got the guy to send me the PU definition which i suspect something
wrong
with it
the PU definition he sent me is
*
PUE PU ADDR=C6,PUTYPE=2,NETID=NETA,MAXPATH=3,
MAXDATA=2012,DLOGMOD=D4A32XX3,ASDP=YET,
LANSW=YES,IDBLK=05D,IDNUM=00006
LUE LU LOCADDR=0,DLOGMOD=IBMRDB,ISTATUS=ACTIVE
PET11 LU LOCADDR=2, ISTATUS=ACTIVE,LOGAPPL=VM
PET12 LU LOCADDR=3, ISTATUS=ACTIVE,LOGAPPL=VM
PET15 LU LOCADDR=4, ISTATUS=ACTIVE,LOGAPPL=VM
PET16 LU LOCADDR=5, ISTATUS=ACTIVE,LOGAPPL=VM
PET17 LU LOCADDR=6, ISTATUS=ACTIVE,LOGAPPL=VM
PET18 LU LOCADDR=7, ISTATUS=ACTIVE,LOGAPPL=VM
PET19 LU LOCADDR=8, ISTATUS=ACTIVE,LOGAPPL=VM
PET20 LU LOCADDR=9, ISTATUS=ACTIVE,LOGAPPL=VM
*
i also got a server traces from HIS and sent to a friend in microsoft who
confirmed that the host is sending only two active LUs however in the
definition there's 8 LUs any ideas what to check or what might be
configured
wrong
thanks alot for your help
/Ahmed
"Neil Pike" <neilpike@compuserve.com> wrote in message
news:VA.00006336.00df71d2@compuserve.com...
Not good news if they're deliberately trying to make it fail!
You could ask them to send you a display of the PU out of netview, that
would
show what was defined/running.
i though so also Neil just wanted to make sure
what i suspect that the mainframe guy is trying to get the project
down
and
he is not doing the right configuration
i guess i will have to visit the client again and look at the PU
setting
myself
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP
|
|
|
| Back to top |
|
 |
Neil Pike
Guest
|
Posted:
Fri Oct 21, 2005 12:51 am Post subject:
Re: TN 3270 problem |
|
|
Note it's an educated guess rather than being the definite cause! :-)
| Quote: | i though that could be the problem also i will try it and update you with
the result :)
thanks alot Neil
|
Neil Pike. Protech Computing Ltd
Microsoft SNA/HIS MVP |
|
| Back to top |
|
 |
|
|
|
|